Skip to content

Validation: src/proteus/interior_energetics/boundary.py

This page tracks the @pytest.mark.reference_pinned tests that anchor the boundary interior backend, the zero-dimensional energy balance of Schaefer et al. (2016)2, against an analytical limit or a cross-implementation comparison. The marker is registered in pyproject.toml. The pins on the radiogenic decay and the solidification front this backend takes from the shared helpers are listed on the common helpers page.

Test id Reference Scope Last compared
tests/interior_energetics/test_boundary.py::test_adiabat_isothermal_limit_reproduces_the_linear_cooling_rate Cross-implementation: the solidification-front energy balance of Schaefer et al. (2016), ApJ 829, 63, section 2, as implemented by the linear melt model with sensible_heat = "whole" With no adiabatic gradient, pressure-independent melting curves and a uniform density, the adiabat melt model's heat capacity must equal M (c_p + L / (T_liq - T_sol)) and its cooling rate must equal the linear model's. Guards against charging only the molten part's sensible heat, dropping the latent term, and a scale or sign slip. 2026-11-13
tests/interior_energetics/test_boundary.py::test_core_heat_capacity_is_added_only_when_requested Closed form: core heat capacity core_heatcap * M_core lumped with the mantle, as in the dummy backend With include_core_heat_capacity the heat capacity gains 450 J kg-1 K-1 x 2e24 kg = 9.0e26 J/K whatever the melt state, so a wholly molten mantle holds 5.7e27 J/K; the reported Cp_eff stays the mantle's own. On an isothermal mantle T_cmb follows T_p one to one. 2026-11-13
tests/interior_energetics/test_boundary.py::test_sensible_heat_whole_cools_the_whole_partly_molten_mantle Closed form: c_p M + L M / (T_liq - T_sol) against c_p phi M + L M / (T_liq - T_sol) Pins 7.46667e27 J/K ("whole") and 6.10987e27 J/K ("molten") on the linear model at 1850.4 K, equal outside the mushy zone, and no jump in sensible heat at the solidus with "whole". The adiabat model gives 7.46667e27 J/K with either setting. 2026-11-13
tests/interior_energetics/test_boundary.py::test_tidal_viscosity_kervazo_hands_the_tides_the_dummy_rheology Kervazo et al. (2021)1, A&A 650, A72: melt-fraction rheology, as eval_rheoparam evaluates it With tidal_viscosity = "kervazo" a wholly solid mantle is handed 1.2567e19 Pa s per shell and a wholly molten one 1.0 Pa s, either side of the 1e9 Pa s viscous-block threshold of LovePy; the convective viscosity is unchanged. 2026-11-10
tests/interior_energetics/test_boundary.py::test_top_melt_fraction_is_the_top_level_of_the_adiabat Cross-implementation: the top level of the full adiabat integration, AdiabatMeltModel.state(T_p).phi[-1] The closed form (T_p - T_sol,top) / (T_liq,top - T_sol,top) used with viscosity_phi = "top" matches the integrated adiabat and exceeds the mass average, because the mantle freezes from the bottom up. 2026-11-10

Energy balance

While the mantle is partially molten, Schaefer et al. (2016) charge sensible heat only to the magma ocean above the solidification radius \(r_s\), and add the latent heat the front releases as it moves:

\[\left\lbrack \tfrac{4}{3}\pi\rho c_p\,(R^3 - r_s^3) - 4\pi r_s^2 \rho L \frac{\mathrm{d}r_s}{\mathrm{d}T_p}\right\rbrack \frac{\mathrm{d}T_p}{\mathrm{d}t} = -4\pi R^2 q_m + M_\mathrm{mantle}\,(Q_\mathrm{radio} + Q_\mathrm{tidal}).\]

The linear melt model (boundary.melt_model = "linear", the default) keeps this form with sensible_heat = "molten", and charges the whole mantle, \(c_p M_\mathrm{mantle}\), with "whole". With a uniform density the molten mass above the front is \(\phi M_\mathrm{mantle}\), so the latent term is \(L M_\mathrm{mantle}\,\mathrm{d}\phi/\mathrm{d}T_p\).

The adiabat melt model (boundary.melt_model = "adiabat") ties the temperature of every level to \(T_p\) along the adiabat, so a change of \(T_p\) moves the whole mantle, solid or molten, and moves the deep levels more than the top. The heat capacity is

\[C = c_p M_\mathrm{mantle} \left\langle \left(\frac{\partial T}{\partial T_p}\right)_P \right\rangle_m + L M_\mathrm{mantle} \frac{\mathrm{d}\phi}{\mathrm{d}T_p} + c_\mathrm{core} M_\mathrm{core} \frac{\mathrm{d}T_\mathrm{cmb}}{\mathrm{d}T_p},\]

with \(\langle\cdot\rangle_m\) the mass mean over the mantle, \(\phi\) the mass melt fraction of the adiabat against the pressure-dependent solidus and liquidus, and the core term present with include_core_heat_capacity. sensible_heat is not read. All three responses come from the melt curve, so the heat drawn along a step closes on the change in mean mantle temperature, melt fraction and core temperature. With a constant \(\nabla_\mathrm{ad}\) the adiabat is \(T \propto T_p\), so \(\partial T/\partial T_p = T/T_p\) exceeds 1 at depth, and taking the responses as 1 understates the heat capacity. A wholly molten or wholly solid mantle has no front and draws no latent heat.

The sensible term does not depend on the melt fraction, so the heat capacity changes only by the latent term where the top of the mantle crosses its solidus. A molten-only sensible term, \(c_p \phi M_\mathrm{mantle}\), would fall there from about 1200 to about 50 J kg-1 K-1, because only a thin top layer is molten and \(\mathrm{d}\phi/\mathrm{d}T_p\) is small; test_adiabat_heat_capacity_follows_the_adiabat checks both.

The pinned test drives both models to the same state, where the adiabat model must reduce to the linear one with sensible_heat = "whole": an isothermal mantle between constant melting temperatures, uniform in density, at a potential temperature between two nodes of the melt curve.

Tides

Under the adiabat model the mantle is handed to the tides modules as num_levels - 1 shells of equal thickness, and the tidal heat in the energy balance is each shell's rate times its mass, summed. A uniform rate reduces to the single-layer H M_mantle / A of the linear model; test_adiabat_tidal_heating_is_summed_over_the_shells checks this to rounding, and that heating only the base shell deposits that shell's share alone.

Structure re-solve

Under the adiabat model the backend publishes the adiabat on every level of the structure's profile (interior_o.temp_profile), and a Zalmoxis re-solve (wrapper.interior_temperature_handoff) follows it on pressure, so the top of the mantle stays at \(T_p\) wherever the re-solve puts it. The re-solve also leaves T_magma and T_surf to the backend: Zalmoxis sets them from the solved structure only in the initial-condition solves. Feeding the shell means back instead, with the top node written to T_magma, raised \(T_p\) by the top shell's adiabatic increment on every re-solve. test_adiabat_structure_resolve_does_not_heat_the_mantle runs five boundary steps without net cooling, each followed by the real re-solve with a stand-in Zalmoxis solve on a temperature-scaled adiabat, and requires T_magma to stay at its starting value; without the change it rises by 300 K.


  1. Kervazo, M., Tobie, G., Choblet, G., Dumoulin, C. & Běhounková, M., Solid tides in Io's partially molten interior: Contribution of bulk dissipation, Astronomy & Astrophysics, 650, A72, 2021. ↩

  2. Schaefer, L., Wordsworth, R.D., Berta-Thompson, Z. & Sasselov, D., Predictions of the atmospheric composition of GJ 1132b, The Astrophysical Journal, 829, 63, 2016. ↩