Skip to content

Validation: src/proteus/interior_energetics/adiabat.py

This page tracks the @pytest.mark.reference_pinned tests that anchor the depth-resolved melt state of the boundary interior module against an analytical limit or a cross-implementation comparison. The marker is registered in pyproject.toml.

The module turns the magma temperature into a melt fraction by integrating a mantle adiabat down the radial profile the interior structure module produced, and comparing it with the tabulated solidus and liquidus at each level's own pressure. Three ingredients come from outside PROTEUS, and each is pinned below: the adiabatic gradient from the Zalmoxis equation of state, the melting curves from the interior lookup tables, and the closed-form isentrope that the explicit stepping approximates.

Test id Reference Scope Last compared
tests/interior_energetics/test_adiabat.py::test_integrate_adiabat_recovers_the_constant_gradient_isentrope Analytical limit of the isentrope dT/dP = nabla_ad T / P Pins the power-law solution T = T_top (P/P_top)^nabla_ad over a pressure ratio of 140. Guards against an exponent that has picked up a factor of two, an adiabat that cools with depth, and a pressure-unit slip. 2026-11-10
tests/interior_energetics/test_adiabat.py::test_zalmoxis_gradient_is_in_the_silicate_range Cross-implementation: the adiabatic gradient Zalmoxis reads for its own structure adiabat, from the equation of state named by interior_struct.zalmoxis.mantle_eos Confirms the gradient reaching the boundary backend is the one Zalmoxis uses, in the range silicate melt occupies (a few to a few tens of kelvin per gigapascal), falling with depth as the bulk modulus stiffens. Also confirms the solidus lies below the liquidus at every level of the tabulated curves and that both rise with depth. 2026-11-10
tests/interior_energetics/test_adiabat.py::test_paleos_melting_curves_follow_the_published_liquidus Published benchmark: Fei et al. (2021, Nat. Commun. 12, 876)2 MgSiO3 liquidus of 6000 K at 140 GPa, and the Belonoshko et al. (2005)1 zero-pressure intercept of 1831 K With the Zalmoxis structure module the melt model takes the PALEOS curves rather than a tabulated folder. Pins the liquidus at both anchors and the solidus at mushy_zone_factor times the liquidus. Guards against the tabulated Wolf and Bower (2018) curves leaking back in (4760 K at 140 GPa), a Pa-versus-GPa slip, and a solidus scaled by the wrong factor. 2026-11-10

Adiabatic gradient

Zalmoxis builds its structure adiabat by stepping

\[\frac{\mathrm{d}T}{\mathrm{d}P} = \nabla_\mathrm{ad}(P,T)\,\frac{T}{P}\]

down the pressure profile, with the dimensionless gradient \(\nabla_\mathrm{ad}\) looked up from the equation-of-state tables: column 8 of the PALEOS tables, or the tabulated dT/dP of the Wolf and Bower (2018)4 and RTPress sets converted as \(\nabla_\mathrm{ad} = (\mathrm{d}T/\mathrm{d}P)\,P/T\). The boundary interior module takes the same gradient through zalmoxis.mixing.get_mixed_nabla_ad, rather than re-reading the tables, so the two cannot drift apart when an equation of state is added or its lookup changed.

The stepping here reproduces the surface-anchored branch of zalmoxis/eos/temperature.py::compute_adiabatic_temperature, including its skip below one bar and its clamp of each level to 100 K to 100000 K.

Melting curves

With the Zalmoxis structure module the solidus and liquidus are always the PALEOS MgSiO3 curves: the Zalmoxis PALEOS-liquidus, Belonoshko et al. (2005) below 2.55 GPa and Fei et al. (2021) above, and a solidus of interior_struct.zalmoxis.mushy_zone_factor times that liquidus (0.8 by default, the Stixrude (2014)3 cryoscopic ratio). These are the curves Zalmoxis uses for a PALEOS mantle, the curves Aragog is given for a PALEOS mantle, and the curves the liquidus_super initial condition is solved against, so the melt state, the structure and the initial condition share one melting model. A melting_dir set alongside is not read by the melt model, and the configuration logs a warning saying so.

With any other structure module the curves are the two-column pressure-temperature files selected by interior_struct.melting_dir, defaulting to Wolf_Bower+2018. They are located by proteus.utils.data.resolve_melting_curve_files, as for the Aragog backend and the Zalmoxis structure: a curve set served through the data manifest (Wolf_Bower+2018, Monteux+600, Monteux-600) is read from its checksum-verified dataset directory, and any other name from FWL_DATA/interior_lookup_tables/Melting_curves/<melting_dir>. They are read through the same proteus.utils.data.load_melting_curve reader. tests/interior_energetics/test_adiabat.py::test_load_melting_curves_reads_the_default_curves_from_their_dataset checks that the default curves load from the dataset directory alone.

tests/interior_energetics/test_adiabat.py::test_paleos_melting_curves_follow_the_published_liquidus pins the PALEOS liquidus against the Fei et al. (2021) value of 6000 K at 140 GPa and the Belonoshko et al. (2005) value of 1831 K at zero pressure.

The Wolf and Bower (2018) liquidus rises from 1980 K at the surface to about 4760 K at 140 GPa; the corresponding solidus runs from 1420 K to about 4340 K. A level whose adiabat lies above the local liquidus is wholly molten, one below the local solidus wholly solid, and the melt fraction is linear in temperature between them.

Mass and volume melt fractions

Phi_global_vol is the shell-volume integral of the local melt fraction and Phi_global its density-weighted counterpart, both taken over the density profile the structure module produced. Because the deep mantle is both denser and closer to its liquidus, the two differ during crystallisation, with Phi_global < Phi_global_vol. They coincide only for a mantle of uniform density, which is the case tests/interior_energetics/test_adiabat.py::test_melt_fractions_agree_on_a_uniform_mantle pins against the closed-form shell integral.

RF_depth is the depth of the adiabat-liquidus crossing as a fraction of the planet radius, \(1 - r_\mathrm{liq}/R_\mathrm{int}\), matching the convention the Aragog and SPIDER backends report.


  1. Belonoshko, A.B., Skorodumova, N.V., Rosengren, A., Ahuja, R., Johansson, B., Burakovsky, L. & Preston, D.L., High-pressure melting of MgSiO3, Physical Review Letters, 94, 195701, 2005. ↩

  2. Fei, Y., Seagle, C.T., Townsend, J.P., et al., Melting and density of MgSiO3 determined by shock compression of bridgmanite to 1254 GPa, Nature Communications, 12, 876, 2021. ↩

  3. Stixrude, L., Melting in super-earths, Philosophical Transactions of the Royal Society A, 372, 20130076, 2014. ↩