zalmoxis.py Validation
Source under test
src/proteus/interior_struct/zalmoxis.py (the liquidus_super initial-condition path:
_resolve_zalmoxis_temperature_mode, _resolve_zalmoxis_cmb_temperature,
load_zalmoxis_configuration).
Reference-pinned tests
| Test ID | Reference | What is pinned |
|---|---|---|
test_liquidus_super_ic::TestPaleosLiquidusSourceOfTruth::test_paleos_liquidus_135gpa |
Fei et al. (2021), Nature Communications, 12, 876 (doi:10.1038/s41467-021-21170-y) | The MgSiO\(_3\) liquidus anchor used by the liquidus_super IC at 135 GPa: T_liq = 6000 * (135 / 140)^0.26 ~ 5943.5 K, pinned to abs=1.0 K. A drift in any fit constant (6000, 0.26, 140 GPa reference) fails immediately. An exponent guard asserts that swapping 0.26 for 0.5 would land ~50 K low, well outside the tolerance. |
Coverage
The liquidus_super mode anchors the initial adiabat at
\(T_\mathrm{liq}(P_\mathrm{cmb}) + \Delta T_\mathrm{super}\), where the liquidus
comes from the Zalmoxis melting_curves fit: the Belonoshko et al. (2005)
branch below 2.55 GPa and the Fei et al. (2021) branch above it. The
reference-pinned test fixes the Fei et al. (2021) high-pressure value at the
1 M\(_\oplus\) reference pressure so any change to the upstream Zalmoxis fit
forces a re-validation of the IC anchor. Companion tests in the same file
check branch continuity at the 2.55 GPa crossover and monotonicity of the
liquidus across the magma-ocean pressure range.